Surgical Mobile C-Arm

Contact us for a quote

Anyview Series
Experience the best x-ray generator and supreme image quality

Identical left, right control panels that allow controlling from either side of the C-arm

Optimized high-quality X-ray image through the best high-resolution camera

Collimator
Iris & shutter collimator & virtual collimator

Maximum free patient space compared to similarly powered C-arms in the market

Built-in software dose meter installation

High-resolution 9 inch image intensifier
(9 inch/6 inch/4/5 inch modes)

High Output power & high-frequency X-ray generator

  • Compact X-ray Generator Design

  • Easy and Economical Maintenance

Advanced mono tank

  • High Output Rotation or Stationary
    X-ray Tubes 

  • Advanced Pulsed Technology

  • High Tube Heal Capacity Compared to Competitors 

General Fluoroscopy

Digital Zoom

Digital Spot Filming

Iris Collimator

Virtual Collimator

Shutter Collimator

Patient Information Menu

Live Edge Enahncement Menu

Intelligent Dose Reduction

Minimum Dose and Best Quality

Image Area

Select the body part of an anatomy, automatically optimize the body part's kV, mA setting and dose

 

Intelligent dose reduction
Select mode, ABS mode, Pulse mode (30 or 15 or 8 fps), activation. 

Lower pulse frequency and pulse width to reduce the dose

Align laser cross pointer on the imaging area

Align collimator on imaging area without x-ray usage

 

 

AIIP (Anyview Intelligent Image Processing)

 

When using the automatic dose reduction mode.

1) System Power Requirement

1) Line Voltage

2) Line Phase

2) X-ray Generator

1) Type

2) Output Power

3) Fluoroscopy

  • Continuous Mode

  • Pulsed Mode

  • Boost Mode 

  • Boost Pulsed Mode

  • ABS Mode

  • Digital Sport Mode

4) Radiography Mode

  • kV Range

  • mA Range

  • mAs Range

3) X-ray Tube

110v/220v 50/60Hz

Single

HFG INVERTER

5.0 kW

0.5-5mA

0.5-5mA

20mA

20mA

YES

YES

40-120kV

20-100mA

0.4-100mAs

1) X-ray Tube Type

2) Max kV

3) Focal Sport

  • Small

  • Large

4) Target Angle

5) Anode Heat Storage Capacity

Stationary

120kV

0.6mm

1.8mm

15°

40kJ

5) Image Intensifier

1) Input Field View Size(inches)

2) Nominal Entrance Field Size(Inches)

3)Contral Resolution(lp/cm

4) Contrast Ration(10%)

9 Inch

9/6/4.5 Inch

52/58/68

30

6) High Resolution Digital Camera

1) Type

2) Pixel Size

CCD

1K*1K

7) Monitor(Included w/ Monitor Stand

1) Type

2) Size(inches)

3) Q-ty

TFT-LCD Dual

19

2

8) Digital Imaging System (DIS)

1) Type​

Anyview Imaging System

9)  Option

1) DAP

2) DSA

YES

YES

4) Collimator

1) Type

2) Opening/Closing

3)Rotation

4) Iris

Motorized

2 Way

360°

Motorized