| Remanufactured OEC 9600 C-arm |
|
| Remanufactured OEC 9600 C-arms from Radiological Imaging Services offer excellent imaging results at a remarkable price. Even more remarkable is our ability to deliver performance and safety features guaranteed to meet or exceed original manufacturers’ specification. Thoroughly remanufactured, our OEC 9600 C-arms are offered with new and upgraded imaging components. We disassemble, mechanically restore, refinish, calibrate and pre-stage each C-arm prior to delivery. Our full line of OEC C-arms offers imaging excellence Ð at about half the price of new! |
|
|
|
|
|
| Features |
|
| Generator |
|
 |
High frequency
|
 |
4.OkW full-wave |
 |
Up to l20kVp |
 |
Up to 75rnA for radiographic film exposures |
 |
Continuous fluoro boost mode up to 12mA (optional) |
 |
Pulsed fluoro mode |
 |
Pulsed fluorography mode up to 40mA (optional) |
 |
Full power from 1IOV 15A |
 |
Patented energy buffer design |
|
|
|
|
| X-Ray Tube |
|
 |
Rotating anode X-ray tube |
 |
Focal spots: 0.3mm and 0.6mm |
 |
Anode heat capacity: 300,000 H.U. |
 |
Anode cooling rate: 60,000 H.U./min |
 |
Housing heat capacity: 1,600,000 H. U. |
 |
Anode diameter: 3.1Ó |
 |
Patented energy buffer design |
|
|
|
| Collimator |
|
 |
Iris collimation with dual opposing semi-transparent shutters allow elliptical, round and rectangular collimation |
 |
Iris and shutters are continuously variable |
 |
All functions remotely controlled from the C-Arm control panel |
|
|
|
| Fluoroscopy Mode |
|
 |
Focal spot: 0.3mm |
 |
kVp range: 40-120 |
 |
Maximum ripple: typically 1% @ 120kVp/5mA |
 |
mA range: 0.2-5.0 normal mode, 1.0-12mA continuous fluoro boost mode (optional on SP) |
 |
Auto and manual modes ¥ Continuous, one-shot or pulsed operation |
 |
ABS varies Ma, kip and camera gain |
 |
User specific ABS tables Pulsed Fluoroscopy Mode |
 |
Focal spot: 0.3mm |
 |
mA range: 0.2-5.0 mA |
 |
Pulse rate: 1, 2, 4. or 8 pulses per second |
 |
Pulse width: 30 or 50 milliseconds |
 |
Computer controlled ABS. mA, kVp and camera gain |
 |
kVp range: 40-120 kVp |
|
|
|
|
| Digital Spot Mode |
|
 |
Standard with the Expanded Surgical Platform (ESP) |
 |
Enhanced digital fluorographic one-shot with 12 mA boost |
 |
Automatically terminates exposure and stores enhanced image to 200 image storage archival disk |
|
|
|
| Radiographic Mode |
|
 |
Focal spot: 0.3mm or 0.6mm |
 |
Focal spot automatically selected |
 |
mAs range: 1-300 |
 |
kVp range: 50-120 |
 |
Cassette holder (optional) -10Ó x 12Ó (9Ó 1.1.) -24cm x 30cm (9Ó 1.1.) -14Ó x 14Ó (12Ó 1.1.) -35cm x 35cm (12Ó 1.1.) |
|
|
|
| Video Imaging System -- 9Ó Image Intensifier |
|
 |
Tri-mode 9Ó/6Ó/4.5Ó image intensifier |
 |
Central resolution (typical): 4.5Ó: 64 lp/cm 6Ó: 56 lp/cm 9Ó: 48 lp/cm |
 |
Peripheral resolution @ 70% radius (typical): 4.5Ó: 64 lp/cm 6Ó : 52 lp/cm 9Ó : 44 lp/cm ¥ DQE: 75% (typical (ct 1.7Hz) 12Ó Image Intensifier Available only with the Expanded Surgical Package (ESP), Vascular Modules or Neuro Vascular Module. |
 |
Tri-mode 12Ó/9Ó/6Ó image intensifier |
 |
Central resolution (typical): 6Ó: 56 lp/cm 9Ó: 50 lp/cm 12Ó: 44 lp/cm |
 |
Peripheral resolution (@ 70% radius (typical): 6Ó 54 lp/cm 9Ó 48 lp/cm 12Ó: 42 lp/cm ¥ DQE: 75% (typical (@ 1.7Hz) |
|
|
|
| T.V. Camera |
|
 |
High resolution CCD camera |
 |
Full frame capture |
 |
360¼ motorized rotation (auto home position) |
 |
On-screen orientation indicator (real-time feedback without fluoro |
 |
Left-right image reversal |
 |
Top-bottom image reversal Negative mode |
 |
Bandwidth: 10.5MHz |
 |
Video signal: Standard RS 170A 60Hz, 525 line |
 |
Aspect ratio: 4:3 |
 |
Computer controlled features: - Gain - Blanking - Camera iris |
|
|
|
| Video Monitors |
|
 |
Dual 16Ó square, black etched anti-glare, anti-static |
 |
525 lines, FastScan flicker-free 73Hz non interlaced VGA compatible |
 |
Ambient room light sensor |
 |
Multi-LED X-ray ÒONÓ indicator |
 |
Remote window/level controls (optional) |
|
|
|
| Image Processing Surgical Platform (Sp) |
|
 |
4 image storage with last image hold 640 x 512 x 10 bit |
 |
Frame averaging (low, medium, high) |
 |
One-shot frame integration (low, medium, high) |
 |
Enhanced integration (low, medium, high) |
 |
MARS (motion artifact reduction) |
 |
Patient annotation keyboard |
 |
Digital window/level |
 |
Real-time auto-histogramming |
 |
Negate |
 |
On-line help menus |
 |
Integrated 2-on-I or I-on-I hardcopy camera (optional) |
 |
Laser aimer/localizer (optional) |
 |
Continuous fluoro boost mode up to 12mA (optional) |
|
|
|
| General Surgical Package (optional) Available only with the Surgical Platform (SP) |
|
 |
64 image storage with last image hold |
 |
16 image collage |
|
|
|
| Expanded Surgical PLATFORM (ESP) Includes all the Surgical Platform (SP) features plus adds |
|
 |
200 image storage with last image hold |
 |
6 image storage on 3 1/2Ó disk (removable) |
 |
16 image collage of 200 image disk |
 |
TrackPad with superkey |
 |
Variable edge enhancement (TrackPad) |
 |
Variable zoom & roam (TrackPad) |
 |
Patient directory with minified image scroll (TrackPad) |
 |
Continuous fluoro boost mode up to 12mA |
 |
Digital Spot Mode |
 |
Anatomical markers |
 |
Relative measurement capability (Track Pad): - Angles - Widths - Lengths |
 |
Procedural dose log (mA, kVp, time, patient) |
 |
Integrated S-VHS VCR (optional) |
 |
Multi function infrared remote control (optional) |
 |
4 fps or 15 fps digital disk (optional) |
|
|
|
| Basic Vascular Module (optional) Available only with the Expanded Surgical Platform (ESP) |
|
 |
Pulsed fluorography mode up to 40mA |
 |
Real-time subtraction ¥ Roadmapping with peak opacification |
 |
Relative measurement capability (TrackPad) - Percent stenosis - Lengths, widths - Angles |
 |
Integrated S-VHS VCR (optional) |
 |
8 fps digital disk - Record/play rate: 8 fps - Record time: 20 seconds - Image storage: 160 digital images - Instant image access with TrackPad - Synchronized to pulse with generator, CCD camera and image processor |
|
|
|
| Vascular Module (optional) Available only with the Expanded Surgical Platform (ESP) |
|
 |
Pulsed fluorography mode up to 40mA |
 |
Real-time subtraction |
 |
Roadmapping |
 |
Peak opacification |
 |
Re-registration (TrackPad) |
 |
Variable landmarking (TrackPad) Mask save/recall |
 |
Relative measurement capability (TrackPad): - Percent stenosis - Lengths, widths - Angles |
 |
Integrated S-VHS VCR (optional) |
 |
4 fps digital disk - Record/play rate: 1, 2 or 4 fps - Record time: 22, 11 or 6 minutes - Image storage: 1,350 digital images - Instant image access with Track Pad - Synchronized to pulse with generator, CCD camera and image processor. |
 |
15 fps digital disk (optional) |
|
|
|
| Neurovascular Module (optional) Available only with the Expanded Surgical Platform (ESP) |
|
 |
Pulsed fluorography mode up to 40mA |
 |
Real-time subtraction |
 |
Roadmapping |
 |
Peak opacification |
 |
Re-registration (TrackPad) |
 |
Variable landmarking (TrackPad) |
 |
Mask save/recall |
 |
Relative measurement capability (TrackPad): - Percent stenosis - Lengths, widths - Angles |
 |
Integrated S-VHS VCR (optional) |
 |
30 fps digital disk - Record/play rate: 1, 2, 4, 8, 15 or 30 fps - Record time: 150, 75, 40, 20, 10 or 5 minutes - Image storage: 9,000 digital images - Instant image access with TrackPad |
 |
Synchronized to pulse with generator, CCD camera and image processor |
|
|
|
| Hardcopy Options |
|
 |
Radiographic film capability |
 |
Integrated hardcopy camera 8Ó x 10Ó 2-on-I or I-on-I formats |
 |
Thermal printer |
 |
Digital laser camera interface - P 831 protocol |
 |
DICOM 3.0 interface |
|
|
|
| System Control |
|
 |
Entire system is computer controlled software upgradeable |
 |
Multi function infrared remote control (optional) |
 |
Hand held X-ray remote control |
 |
Multi function footswitch |
|
|
|
 |
| Remanufactured OEC 9600 C-arm |
|
| Radiological Imaging Services' remanufactured OEC C-Arms are offered with new imaging systems and affordable options. Each system is completely disassembled, inspected, and mechanically restored. This thorough process incorporates both upgraded and new components are then refinished with our three step paint process and the completed system is thoroughly re-tuned, aligned, and calibrated to meet OEM specifications.
Both C-Arm and workstation are light and compact for easy transportation and maneuverability. Balanced weight distribution and user friendly steering provide for push or pull operation.
EasyOp user friendly, one button operation of all functions. |
|
|
|
|
|
| On-screen orientation indicator allows image rotation to indicated position without generating X-rays. |
|
Special Procedures Options
Real-time Subtraction |
|
 |
Allows a dynamically subtracted view during a contrast study or any study where better visualization of a foreign object is needed. |
 |
Masked image is automatically formed and subtracted continuously from an averaged (2 to 32 frames selectable) fluoro image at the rate of 30 FPS. |
 |
Produces a continuous visualization of contrast moving through vessels. |
|
|
|
| Cholangiography |
|
 |
Fluoro boost and peak opacification are provided for this procedure. |
 |
Pulsed fluoroscopy |
 |
4 F/S digital disc (optional). |
|
|
|
| Roadmapping |
|
 |
Live images are subtracted from an opacified contrast image, providing a map to follow during critical catheter placement. |
 |
Roadmapping allows a greatly simplified method for catheter placement. |
 |
The procedure calls for the formation of a contrast opacified mask image of the vessel in which the catheter is to be placed. |
 |
This is stored and subtracted from the continuous fluoro catheter placement procedure. |
 |
The result is a clear visual path, or roadmap of the route to be followed by the catheter. |
 |
Background information is subtracted. |
|
|
|
| Peak Opacification |
|
 |
As the contrast moves through the vessels of interest, it is desirable to stop a frame at an optimal point of the sequence. |
 |
Because the contrast is moving, it is unlikely that the entire vascular tree will be optimally opacified at any one time. |
 |
Peak Opacification remembers the maximum, or peak, contrast reached along each point of the vasculature. |
 |
This allows visualization of the complete vasculature independent of flow dynamics. |
|
|
|
| Mask Manipulation |
| Save, recall. |
|
 |
| Remanufactured OEC 9400 C-arm |
|
Remanufactured OEC 9400 C-arms from Radiological Imaging Services offer affordable, state-of-the-art imaging technology. Thoroughly remanufactured, our OEC 9400 C-arms are offered with both new and upgraded imaging components. And they're guaranteed to deliver performance and safety features that meet or exceed original manufacturer's specifications.
We disassemble, mechanically restore, refinish, calibrate and pre-stage each C-arm prior to delivery. Our full line of remanufactured OEC C-arms offers imaging excellence — at an affordable price. |
|
|
|
|
|
| Features |
| Integrated System |
|
 |
Digital image storage and review. |
 |
Microprocessor control of all functions. |
 |
User programmable technique settings. |
 |
Self-diagnostic program. |
 |
Stand alone monitor for ease of hard copy on remote multi-format cameras. |
 |
Dual power system can be changed to operate on either 110 or 220 volts. |
|
|
|
| X-ray Generator virus |
|
 |
High frequency 2.5 kHz |
 |
7.5 KW Full-Wave. |
 |
Up to 120 kVp, up to 100 mA for radiographic exposures. |
 |
Fluoro boost/ pulsed fluoro capability. |
|
|
|
| X-Ray Source |
|
 |
Rotating anode. |
 |
Focal spots: 0.3 mm and 1.0 mm |
 |
Anode heat capacity: 300,000 HU |
|
|
|
| Fluoroscopy Mode |
|
 |
Focal spot: 0.3 mm |
 |
kVp range: 40 — 120 kVp |
 |
ma range: 0.2 — 5.0 (20 ma max boost) |
 |
Continuous one-shot or pulsed fluoro. |
 |
ABS varies ma, kVp and camera gain. |
 |
User selects ABS tables for orthopedics, chest, and low dose applications. |
 |
Collimation is continuously adjustable and rotatable. |
|
|
|
| Radiography Mode |
|
 |
Focal spot 0.3 mm and 1.0 mm |
 |
kVp range: 50 — 120 kVp |
 |
mAs range: 1 — 300 mAs |
 |
Focal spot size automatically selected. |
|
|
|
| Collimation is continuously adjustable and rotatable. |
|
| Image Intensifier |
|
 |
Choice of 6” or tri-mode 9”/6”/4” image intensifier. |
 |
Resolution: |
| |
— 44 lp/ cm central (9” mode) |
| |
— 42 lp/ cm peripheral (9” mode) |
 |
Contrast ratio: › 28:1 (9” mode) |
|
|
|
| High Resolution, Low Noise Camera |
|
 |
Designed for fluoroscopy. |
 |
Full 360° motorized rotation with left-right manipulation. |
 |
Negative mode. |
 |
Automatic gain control. |
 |
Camera tube type: Vidicon |
 |
On-screen orientation indicator. |
 |
Left/right, top/bottom image reversal. |
|
|
|
| Image Processing |
|
 |
Focal spot 0.3 mm and 1.0 mm |
 |
Motion artifact reduction (MARS). |
 |
Digital image enhancement. (windowing). |
 |
Variable edge enhance (track ball). |
 |
Removable disk (on ESP and above). |
|
|
|
| Image Storage Options |
|
 |
Radiographic film capability. |
 |
Sixty-image digital storage. |
 |
Video tape recorder (VTR). |
 |
Multi-format camera. |
 |
New thermal printer. |
|
|
|
| Mechanical Specifications |
|
 |
Free space in arc — 6” I.I.: 29.5” (75 cm) |
 |
Free space in arc — 9” I.I.: 27.0” (69 cm) |
 |
Depth of arc: 23”, movement: 111° |
 |
Travel: — Vertical: 18” motorized. — Horizontal: 8” |
 |
L-arm rotation: ± 360° motorized |
|
|
|
| Reversible C-arm: Manual (flip-flop) |
|
| Input Power |
|
 |
100/120 VAC, 15 AMP |
 |
200/220/240 VAC, 12 AMP |
 |
50 Hz (optional) |
|
|
|
| Main C-arm Frame (stored)/ Monitor Cabinet Dimensions |
|
 |
Length: 74.5” (189 cm)/ 32” (81 cm) |
 |
Height: 66.2” (168 cm)/ 65” (165 cm) |
 |
Depth: 34” (86 cm)/ 27” (63 cm) |
|
|
|
| Remanufactured OEC 9400 C-arm |
|
| Radiological Imaging Services remanufactured OEC C-Arms are offered with new imaging systems and affordable options. Each system is completely disassembled, inspected, and mechanically restored. This thorough process incorporates both upgraded and new components including a new Vidicon camera pick-up tube. Finished components are then refinished with our three step paint process and the completed system is thoroughly re-tuned, aligned, and calibrated to meet OEM specifications. |
|
|
|
 |
| Complete Tear-Down |
|
| All mechanical and electronic systems are functionally and cosmetically inspected, evaluated and replaced as needed. |
|
|
|
|
|
 |
| Extended Glassware Warranty |
|
| We stand behind each remanufactured C-arm with a non-prorated, three year glassware — one year parts and labor warranty. |
|
|
|
|
|
 |
| High Resolution Video Monitors |
|
| | | |